Page 1

Product Specification X2200AAI1#128694 X2200AAI Typical characteristics Standard charge characteristics Specifications of single cell 1.8 Charge:0.1Cx15h 1.7 Nominal voltage 1.2V 1.6 Voltage (V) 0.2C 0.5C 1.5 Discharge Discharge Capacity 1.4 Minimum 275min 108min 1.3 Typical 300min 116 min 1.2 mm 1.1 Diameter 0 2 4 8 10 12 14 16 Dimensions 14.5-0.7 Charge time (hours) Height 50.0-1.0 Rapid charge characteristics 1.8 gram Weight (approximately) Charge:0.5C×2.1h 1.7 29.4 1.6 0 InternalImpedance 35 mΩ (max) Voltage (V) -20 1.5 at1000Hz After Charge 1.4 40 Standard 220mA(0.1C)×15h Charge 1.3 Rapid 1100mA(1.0C)×1.05h 1.2 D。 Charge temperature Standard 1.1 Ambient 0℃Cto40℃ 0 02 40 60 08 100 120 140 160 Charge time (minutes) Rapid 0°Cto40°℃ Discharge characteristics Discharge -20°Cto50°℃ 1.5 Storage -20℃to Charge:0.5C×2.1h 30°℃ 1.4 1.3 Voltage (V) 1.2 Dimensions with tube (unit mm) 1.1 -0.20 1.0 1.0C 0.5C 0.9 0.8 0 20 40 60 80 100 120 140 Discharge capacity (%) Cycle life characteristics 120 Nominal capacity (%) 100 80 9 0 20 14.5-0.7 0 100 200 300 400 500 600 Number of cycles life curve Charge retention curves of Ni-MH cylin- Note: drical cell at various storage temperature 1. Nominalcapacity,ratedat0.2C20C. 110 2. Average capacity, for reference only. Capacity Reserve (%) 100 0 3. 06 Weight and internal impedance are for reference. 80 4. Standard according as lECof test cycle life. 20 70 09 50 40 30 40 02 10 00 0 5 10 15 02 25 30 35 40 45 05 Time (days) energy insideGmbH·IndustriestraBe12·D-97618Niederlauer Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.

Page 2

Product Specification X2200AAI1#128694 1. RATINGS Description Unit Specification Condition NominalVoltage A 1.2 Unit cell Typical Capacity min 300 StandardCharge/Discharge NominalCapacity mAh 2200 StandardCharge/Discharge MinimumCapacity min 275 StandardCharge/Discharge mA 220(0.1C) Ta=0~40°C StandardCharge hour 15 (see note) 440(0.2 C)~1100 (0.5C) -∆V = 5 mV/cell mA with charge termination Timer cutoff=105% input control capacity Fast Charge Temp.cutoff=40~45C 6.0 approx. (0.2 C) hour dT/dt=0.8°C/min(0.5to1.0C); 2.1 approx.(0.5 C) 0.8~1°C/min(1C) Ta=0~40C TrickleCharge mA 110 (0.05C)~220(0.1 C) (see note) Discharge Cut-off A 1.0 Unit cell Voltage Maximum Discharging Ta=0~50°C mA 1100 (0.5C) Current 1.0 V/cutoff -20~+25 (within 1 year) -20~+30 (within 3 month) Storage Temperature D。 * -20~+40 (within 1 month) -20~+50 (within 1 week) TypicalWeight 6 29.4 approx. * 2.PERFORMANCE Before proceed the following tests, thecells shouldbedischarged at0.2Cto1.0Vcutoff.Unless otherwise stated,tests shouldbedone within one monthofdelivery under the following conditions: Ambient temperature: 20℃C±5℃ Relative Humidity: 65±20% NoteStandardCharge/DischargeConditions: Charge:220mA(0.1C)×15h Discharge:440mA(0.2C)to1.0V/cell Test Unit Specification Condition Remarks Capacity min ≥275 StandardCharge/Discharge Up to 3 cycles are allowed Open circuit A ≥1.25 Within1hafter standard charge Unit cell Voltage (OcV) Internal Impedance mΩ ≥35 Upon fullychargeat1kHz ¥ (Ri) High Rate Dis- min ≥108 StandardCharge/rest30min Up to 3 cycles are charge (0.5 C) discharge at0.5Cto1.0V allowed Rate Discharge min ≥N/A StandardCharge/rest30min Upto3 cycles are (2.0 C) discharge at2.0Cto0.9V allowed Low Temperature min ≥240 StandardCharge, 1.0 V/cell Discharge Storage:24hat0±2C Cut-off 0.2Cdischarge at0±2C Overcharge N/A No conspicuous 0.1Ccharge for48h * deformation and/ or leakage energy insideGmbH·IndustriestraBe12·D-97618 Niederlauer Manufacturer reserves the right to alter or amend the design, model and specificationwithout prior notice.

Page 3

ProductSpecification X2200AAI1#12894 Charge reserve min ≥180min Standard charge Storage:28days, 1.0 V/cell Standard discharge (0.2C) Cut-off IEC Cycle Life Test Cycle ≥500 IEC61951-2(2003)7.4.1.1 * Humidity N/A No leakage Standardcharged,standfor14days ¥ at33±3℃Cand80±5%ofrelative humidity External Short N/A No fire and no After standard charge, short-circuit ¥ Circuit explosion the cellat20C ±5C until the cell temperature returns to ambient temperature (cross section of the wire or connector shouldbe more than 0.75 mm2). Safety Device N/A No explosion Forceddischarge at0.2Cto a final Leakage ofelectro- Operation voltage of 0 V,then the current be lyte and Deforma- increased to1 C and forced dis- tion are acceptable charge continue for 60 min. Free falling (drop) N/A △V<0.02V/cell Charge at0.1Cfor16h,andthen * △Ri<5 %/cell leave for24 h, check battery be- fore/after drop. Height:50cm Thickness of wooden board:30mm Direction is not specified Test for 3 times Notes: 1. Ta:Ambient Temperature 2. Approximate charge time from discharged state,for reference only. 3. Please activate the battery once every 3 months according to the following method:Charge at 0.1 C for 15h,rest10min,thendischargewith0.2Cto1.0 V/cell,rest10min,thencharge at0.2Cto150min. 3.PRECAUTIONSTOENSURE THESAFETYONBANDINGBATTERY: 1. Batteries shouldbe charged prior to use. 2. When using a new battery for the first time or after long term storage, please fully charge the battery before use. 3. For charging methods please reference to our technical handbook. 4. Use the correctchargerforNi-Cd or Ni-MHbatteries. 5. Do not reverse charge batteries. 6. Do not short circuit batteries, permanent damage to batteries may result. 7. Do not incinerate or mutilate batteries, may burst or release toxic material. 8. Do not solderdirectly to cells or batteries. 9. Do not subject batteries to adverse condition such as extreme temperature, deep cycling and excessive overcharge/overdischarge. 10. Store batteries in a cool dry place. 11.DonotmixXCellbatteries withother battery brands or batteriesof a different chemistry such as alkaline and zinc carbon. 12. Do not mix new batteries in use with semi-used batteries, overdischarge may occur. 13. Avoid batteries being used in an airtight compartment. Ventilation should be provided inside the bat- tery compartment; otherwise batteries may generate hydrogen gas, which could cause an explosion if exposed to an ignition source. 14.When connecting a battery pack to a charger, ensure correct polarity. 15. If find any noise, excessive temperature or leakage from a battery, please stop its use. 16.Whenthebattery ishot, please donottouch it and handle it,until ithascooled down. 17.Do not remove the outer sleeve from a battery pack nor cut into its housing. 18.When find battery power down during use, please switch off the device to avoid overdischarge. 19.When not using a battery, disconnect it from thedevice. 20.Unplug a battery byholding the connector itself and not by pulling at its cord. 21.After use, if the battery is hot, before recharging it, allow it to coolin a well-ventilated place out of direct sunlight. 22. Never put a battery into water or seawater. energy insideGmbH·IndustriestraBe12·D-97618Niederlauer Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.

Page 4

Product Specification X2200AAI1#128694 23. During long term storage, battery shouldbe charged and discharged once every half a year. 24. Do not attempt to take batteries apart or subject them to pressure or impact. Heat may be generated or fire may result. The alkaline electrolyte is harmful to eyes and skin,and it maydamage clothing upon- contact. 25. Keep away from children. If swallowed,contact a physician at once. 4. APPEND: IEC619514.4Endurance in cycles Before the endurance incycles test,thecell shall be discharged at0.21.Ato a final voltageof1.0 V/cell The following endurance test shall then be carried out, irrespective of cell designation, in an ambient tempera- ture of20C±5C.Charge and discharge shall be carried out at constant currentthroughout,using the condi tions specified in table 5.Precautions shall be taken to prevent the cell-case temperature from rising above 35C during the test, by providing a forced air draught if necessary. NOTE:Actual cell temperature, not the ambient temperature, determines cell performance. Table5-Endurance incycles Cycle number Charge Stand inCharged condi- Discharge tion 1 0.1CAfor16h None 0.25CAfor2h20min2}) 2to 48 0.25CAfor3h10min None 0.25CAfor2h20min2) 49 0.25CAfor3h10min None 0.25CAto1.0 V/cell 50 0.1CAfor16h 1hto4h 0.2CAto1.0 V/cell It is permissible to allow sufficient open-circuit rest time afterthe completionofdischarge at cycle50, so as to start cycle51 at an exact two-week internal. A similar procedure may be adopted at cycles100, 150,200,250,300,350,400and450. If cell discharge voltage drops below1.0 V/cell, discharge maybediscontinued. Cycles1to50 shall be repeated until the discharge duration on any50th cycle becomes less than3h at this stage,a further cycle as specified forcycle50 shall be carried out. The endurance test is considered complete when two such successive cycles give a discharge duration less than3h.The number ofcyclesobtainedwhen the test is completed shall be not less than500. energy insideGmbH·IndustriestraBe12·D-97618 Niederlauer Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.